N74080 Back Off Distance
The additional moving distance after the end of fine positioning in returning to
machine origin.
The positive value means the positive direction and the negative one means the
negative direction.
N74100 Lead screw Pitch
The axial distance or degree between the corresponding points of two adjacent
teeth on the threads.
Worry values cause the wrong axial distance or degree.
N74110 Min. Distance of Coar/Fine Switches
To detect whether the distance between coarse switches and fine switches is too
close in returning to the machine origin.
Range: (0, screw pitch/2)
The valid range of distance between coarse switches and fine switches: (minimum
distance, screw pitch- minimum distance)
For an absolute motor, Default setting can meet the demand; For an incremental
motor, it can be set to a small one.
N75210 Fixed Presetter Position
The machine coordinates of the fixed presetter.
N79110 Fixed Point Position
The machine coordinates of the fixed position.
5.11 Other Parameters
N42001 Enable G28
Whether to support G28 command.
N42031~N42035 Enable Driver Registration
Whether to enable drive registration function.
Only WISE series drives support this function.