42 EN RESCUE-PACK Plus
WM 66531 2023-01
9 Faults
Oxygen cylinder is not seated
securely
Tension belts for oxygen cylinder
not fitted properly
Fit tension belts for oxygen
cylinder properly (see 8.6, p. 39).
Tension belts for oxygen cylinder
defective
Replace tension belts for oxygen
cylinder (see 6.2, p. 26), (see 8.6,
p. 39).
Strap guide defective Replace emergency backpack.
Accessory for device cannot be
secured properly, e.g., breathing
circuit
Magnetic fastener defective Replace magnetic fastener.
Emergency backpack cannot be
closed
Zipper defective Replace emergency backpack.
Emergency backpack cannot be
carried on the shoulder
Shoulder strap defective
Replace shoulder straps (see 6.6,
p. 29), (see 8.2, p. 37).
Fault Cause Remedy