Rotary indexing ring NR
Commissioning
WARNING
UNINTENDED EQUIPMENT OPERATION
Incorrect or unsuitable parameter values or settings can cause unintended
movements, trigger signals, and compromise functional safety.
Failure to follow these instructions can result in death, serious injury, and
equipment damage.
Verify that parameter values and settings can only be modified by authorized
personnel who fully understand each and every effect of such a modification.
Verify that all parameter values and settings are correct by performing a test run.
WARNING
ELECTROMAGNETIC RADIATION
Failure to follow these instructions can result in death, serious injury, and
equipment damage.
Verify compliance with all international, national, and local directives, standards,
and safety regulations, including all regulations concerning workplace safety and
prevention of accidents, with regard to electromagnetic radiation.
Take all necessary measures to ensure that persons with active medical implants
(such as heart pacemakers or insulin pumps), metal implants, and magnetically
or electrically conductive objects are not exposed to the electromagnetic fields
generated by the motor.
Power on the power supply to the product via the main switch.
Check the following points during commissioning:
Operating state, potential error conditions, and protective equipment
During commissioning, perform tests for all operating states and error conditions. In doing so,
verify that all protective equipment operates as planned and required.
Correct operation of the motor
There are no overloads.
There are no unusual fluctuations in the speed of rotation. Immediately stop the product in the
case of overloads or unusual fluctuations in the speed of rotation and verify correct mounting.
Noise emission
Excessive noise emission can be an indication of incorrect mounting, for example, an uneven
ground that causes mechanical stress at the rotary ring. Immediately stop the product in the case
of high noise emission and verify correct mounting.
Heat
Verify that the heat dissipation is sufficient and that the specified climatic environmental conditions
are respected by performing a test run under maximum load conditions.
If the product and/or the machine into which the product is incorporated is temporarily
decommissioned, it must be recommissioned. For recommissioning, the same prerequisites must be
met as for initial commissioning.
Perform the same tests for each recommissioning of the product as for initial commissioning.
42 / 62
Mounting instructions_062019_1.0_en

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WEISS NR Series and is the answer not in the manual?

WEISS NR Series Specifications

General IconGeneral
BrandWEISS
ModelNR Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals