4. Mount the cover [4] by means of the screws.
5. Remove all tools and equipment.
6. Perform a test run.
15.5 Replacing the toothed belt
DANGER
ELECTRIC SHOCK CAUSED BY LIVE PARTS
Failure to follow these instructions will result in death or serious injury.
Disconnect the mains supply voltage before performing the work and ensure that
it cannot be switched on.
Verify that no hazards can be caused by electrically conductive objects.
Verify that all cables for the power supply are disconnected from power.
WARNING
UNANTICIPATED MOVEMENT OF THE ROTARY RING/THE ROTARY RING
The gear is not self-locking. When the drive and the output flange/rotary ring are
decoupled, the output flange/rotary ring can move.
Failure to follow these instructions can result in death, serious injury, and
equipment damage.
Block or safeguard the output flange/rotary ring in such a way that a movement
of the output flange/rotary ring is safely prevented before releasing the holding
brake or decoupling the drive and the output flange/rotary ring.
WARNING
MISSING PROTECTIVE EQUIPMENT
Failure to follow these instructions can result in death, serious injury, and
equipment damage.
Immediately reinstall protective equipment that you may have removed to
perform maintenance work after having completed the maintenance work and
verify the effectiveness of the protective equipment.
Mounting instructions_062019_1.0_en
55 / 62

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WEISS NR Series and is the answer not in the manual?

WEISS NR Series Specifications

General IconGeneral
BrandWEISS
ModelNR Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals