7.3.4. Switching Output Poti
Potentiometer Vary switching point
Switching point in mm The switching point can be manually varied by pressing the “+” or “–” keys. You
can keep a key pressed for a longer time in order to make larger numerical jumps.
7.3.5. Switching Output Hysteresis
The switching hysteresis is the difference between the switch-on and the switch-off points.
Hysteresis Vary hysteresis
Hysteresis in mm The hysteresis can be increased by pressing the “+” key. The hysteresis can be
reduced by pressing the “–” key. The minimum hysteresis depends on the filter that
has been set (see chapter “4. Device Features” on page 5). You can keep a key
pressed for a longer time in order to make larger numerical jumps.
7.3.6. Switching Output Window Size
Note: The menu item is only visible if a Window Teach has been conducted.
Window size Vary window size
Window size in mm The window size can be increased by pressing the “+” key. The window size can
be reduced by pressing the “–” key. The minimum value that can be set is 10 mm.
You can keep a key pressed for a longer time in order to make larger numerical
jumps.
7.3.7. Switching Output NPN/PNP
NPN/PNP Configuration of the outputs
PNP
NPN
Pushpull
3 Back
7 Run
PNP: The load or the evaluation device is connected between the negative
pole (reference) and the output. When switched, the output is con-
nected via an electronic switch to the positive pole.
NPN: The load or the evaluation device is connected between the positive
pole (reference) and the output. When the Sensor switches, the output
is connected via an electronic switch to the negative pole.
Pushpull: Push-pull output. Functions like an electronic switch that selectively
couples the output to the positive pole or the negative pole