7.13. Password
Password protection prevents against unintended changing of the set data.
Note: The menu item is only visible if Expert Menu “On” has been set.
Password Set password functionality
Enable
Change
Lock
3 Back
7 Run
Enable: Turn password protection on or off. If password protection is acti-
vated, the operation of the Sensor is disabled after supply power has
been interrupted and is only enabled after successful password input.
Change: Change password.
Lock: Locking Sensor causes an immediate disabling of operation if Activate
Password is set to “On”.
If the password function has been activated, the password must be entered each time supply power to the
Sensor is interrupted. After entering the correct password with the + or – key, the entire menu is enabled and
the Sensor is ready for use.
• The password function is deactivated upon shipment from the factory.
• Passwords can be selected within a range of 0000 to 9999.
Be sure to make a note of the new password before exiting the “change password” function! If the password
is forgotten, it must be overwritten with a master password. The master password can be requested by e-mail
from techbox@automationdirect.com.
8. Maintenance Instructions
• This wenglor Sensor is maintenance-free.
• It is advisable to clean the lens and the display, and to check the plug connections at regular intervals.
• Do not clean with solvents or cleansers which could damage the device.
9. Proper Disposal
wenglor sensoric gmbh does not accept the return of unusable or irreparable products. Respectively valid
national waste disposal regulations apply to product disposal.