ENGINE
TROUBLESHOOTING
The following troubleshooting chart describes certain problems
and causes relating to engine service. Also note there is a
Diagnostic Troubleshooting section that follows.
Problem
Engine
does
not
crank.
Engine
cranks,
does
not
start
(engine
will
crank
8
seconds)
Engine
starts,
runs
and
the
shuts
down.
Engine
hunts.
Engine
misfires/back
firing.
Engine
overheats/engine
temp
LED
is
illuminated.
Exhaust
temp
LED
is
illuminated.
Low
oil
pressure/oil
pressure
LED
is
illuminated.
No
DC
charge
to
starting
battery.
Engine
cranks,
stops.
Check
engine
LED
comes
on.
Note:
When servicing the engine/generator, the main circuit
breaker (control panel) disconnects all
AC
power and can
be
switched
off
and
reset manually.
Possible
Cause
1.
DC
panel
breaker
OFF.
2.DC
battery
OFF.
3.K2
relay
faulty.
4.Starter
solenoid
faulty.
5.DC
battery
low/dead.
6.
Faulty
starter
solenoid.
7.
Water
filled
cylinder.
1.Fuel
starvation.
2.Air
in
fuel
system.
3.Fouled
spark
plugs.
4.Faulty
ignition
coil.
1.Fuel
starvation.
2.Air
in
fuel
system.
3
..
Faulty
shutdown
switch/sensor.
4.
Faulty
fuel
pump.
1.Air
in
fuel
system.
2.Faulty
fuel
pump.
3.Low
octane
fuel
(lower
than
89).
4.Faulty
MAG
pick-up.
1.Low
octane
fuel
(lower
than
89).
2.Dirty
air
intake
screen
screen.
3.High
tension
ignition
wires.
4.
Flywheel
loose.
5.
Exhaust
restriction.
6.Worn/fouled
spark
plug.
7
.Faulty
ignition
module.
1.
Raw
water
coolant
flow
obstruction.
2.Coolant
level
low.
3.
Faulty
impeller.
4.Pump
belt
loose/broken.
5.0bstructed
by-pass
hose.
6.Stuck
thermostat.
1.Loss
of
coolant
flow/faulty
pump.
2.Faulty
exhaust
temperature
switch.
1.0illevellow.
2.Faulty
oil
pressure
sendor.
3.Faulty
oil
pressure
switch.
4.011
viscosity
incorrect.
1.Circuit
fuse
faulty/blown.
2.Faulty
circuit
connection.
3.Faulty
regulator.
1.Data
Log
needed
to
determine
cause.
2.0xygen
Sensor.
3.Low
charge
in
starting
battery.