Engine RUN State Shutdowns: (€ontinued
fr~m
previous page)
Warning
Description
Parameters
Possible
cause
dead battery
Battery Voltage
Low
Less
than
10
volts
o
blown
fuse
12
o faulty regulator or charging circuit
o loose connection or corroded wiring
o faulty exhaust temperature switch
13
Exhaust Temperature High
Open circuit
o loose connection or corroded
Wiring
o seawater
flow
blocked
.
14
External
Alarm
Open circuit
external alarm fault
(i.e.
Fireboy)
o loose connection or corroded
Wiring
Wideband
02
Sensor (WB02)
·
ECU
measures
o
excessiyely
rich or lean combustion
15
Reading
Out of
Table
A
<.70
or A> 2.oo, which
loose connection or corroded wiring
is out of the table range
o
oxygen
sensor faulty
Wideband
02
Sensor (WB02)
A reading not crossing
o
excessively
rich or lean combustion
16
Failure
to
Cross
Stoich
above
and below
A=l.OO
at
o dirty or
clogged
fuel
injector(s)
least once per minute
o insufficient fuel supply or pressure
Wideband
02 Sensor (WB02)
Heater current out of
.,
loose connection or corroded wiring
17
Heater failure
normal range
oxygen
sensor faulty