8
Accessories
7
Technical
specications
6
Errors
Troubleshooting
5
Maintenance
and care
4
Operation
Programming
3
Installation
2
Product
description
1
Important
information
General
information
Aug. Winkhaus GmbH & Co. KG · Berkeser Str. 6 · D-98617 Meiningen www.winkhaus.de
Subject to technical changes
Print-no. 504 474 4
01/2017
Installation, Operating and Maintenance
Instructions blueMatic EAV
47
Figure 3.6.4-1: Wiring blueMatic EAV and Fingerprint Sommer ENTRAsys FD (sash side)
No. Description
1
Sash part seperable cable transition KÜ-T1-SOMMER-EAV * (with 5-pole plug for receiver ENTRAsys FD)
2
Frame part STV-KÜ-T1 RT Kabel 4M
3
Connecting cable 3 m, 3-wire for motor * (with 3-pole plug for receiver ENTRAsys FD)
4
Motor housing EAV **
5
Fingerprint ekey ENTRAsys FD (or other access control company Sommer) ***
6
Radio receiver ENTRAsys FD (company Sommer) ***
7
Connection cable from receiver to fingerprint scanner ENTRAsys FD (company Sommer)
***
*
at shipment Winkhaus STV-KÜ-T1 SET FT ZK-SO+EAV FT1M+KABEL3M
** at shipment Winkhaus, unmounted, for retrotting mechanical locking system
*** at shipment Sommer
Detail A: ENTRAsys FD radio receiver
B2
B1
B3
B1:
Connection from sash part
cable transition to the
radio receiver ENTRAsys
FD (plug-in, 5-pole plug)
B2: Connection from radio
receiver ENTRAsys FD to
the motor housing EAV
(plug-in, 3-pole plug)
B3: Connection from radio
receiver ENTRAsys FD to
the ngerprint ENTRAsys
FD (plug-in)
Detail B: Connections frame part STV-KÜ-T1 RT
Kabel 4M or signal line frame power supply 12 V DC
}
external opening signal
}
free
white + 12 V DC
brown 0 V
yellow
green
grey
pink
green/yellow = input for external potential-
free contact (e. g. unlocking via
intercom/open button)
NOTICE! max. 40 m extendable