Electric Cooktop -2
Troubleshooting Guide
5-3
AMBIENT TEMPERATURE TEST (continued)
2. The triple zone bar lights will show 4 LEDs and ash at a rate of .75 seconds ON and .25 seconds OFF.
3. The timer display illuminates Ambient Control Temperature in °F.
4. A press of the [-] key on the triple zone element will step the user back one test to the Checksum Info.
HEAT SINK THERMISTOR TEMPERATURE TEST
1. To enter the Heatsink Temperature test, while in the Ambient temperature test, touch the [+] keypad of the triple zone
element controls.
2. The triple zone element bar lights will show 5 LEDs and ash at a rate of .75 seconds ON and .25 seconds OFF.
3. The timer display illuminates Heat Sink THERMISTOR temperature in °F.
6. A press of the [-] key on the triple zone element will step the user back one test to the Control Temperature Test.
ERROR CODE INDICATOR
1. To enter Error Code Indicator, while in the heatsink temperature test, touch the [+] key of the triple zone element.
2. The triple zone bar lights will show 6 LEDs and ash at a rate of .75 seconds ON and .25 seconds OFF.
3. The 1200W element controls will illuminate 0-16 bars based on the amount of error codes written to memory. If no
errors were recorded, zero bar lights will illuminate.
4. The 3-digit display will show the corresponding error code stored in memory. (See Error Code Chart at the end of
section 5)
5. The user will touch the [-] / [+] keys of the 1200W element to step through each error.
6. With each error, the number of bar lights of the 1200W will correspond to the error that is shown. (e.g. if there are
6 errors, the 1st error to appear on the display upon entry will be the 6th error and there will be 6 LEDs lit, user
presses the [-] key and the 5th error stored will show in the display and there will be 5 LEDs lit.
7. After the last error, a key touch of [+] will return to the 1st stored error and corresponding LEDs will be lit.
8. The 3-digit display will show the corresponding error code stored in memory. See below for speci c errors. If there
are no errors a “—” will be displayed.
9. A touch and 5 second hold of the [OFF ON] key on the single zone (1200W) control will clear the error history and
leave it blank.
10. To step back to the Heatsink Temperature test, the user can touch the [-] keypad of the triple zone element control.
SOFTWARE VERSION
1. To enter Software Version, while in ERRORS touch the [+] keypad of the triple element controls.
2. The triple zone bar lights will show 15 LEDs and ash at a rate of .75 seconds ON and .25 seconds OFF.
3. The timer display will scroll the software version in the following format: X MJMNBD. (X = d for display board and P
for power module. MJ = major, MN = minor, BD = build)
4. To toggle between display boards software version and power module software version, the user will touch either the
[-] or [+] keys on the 1200W control.
5. A press of the triple zone [-] key will step the user back to the Power Cycling Information.
SELF TEST
1. To enter Self Test, from the Software Version touch the [+] keypad of the triple zone element controls.
2. The triple zone bar lights will show 16 LEDs and ash at a rate of .75 seconds ON and .25 seconds OFF.
3. The 1200W control will be ashing indicating that the test has not run.
4. A press of the [OFF ON] keypad on the 1200W control will start the test.
5. A moving hyphen in the 3-digit display will indicate that the test is running.