721DSC for Marine Propulsion Application Manual 26004
Woodward
2
8
7. Torque Lmt P3, %
Torque Lmt P3, % is the maximum actuator output current in percent at the third
torque limit.
8. Torque Lmt P4, rpm
Torque Lmt P4, rpm is the engine speed in RPM at the fourth torque limit.
9. Torque Lmt P4, %
Torque Lmt P4, % is the maximum actuator output current in percent at the fourth
torque limit.
10. Maximum Fuel Limit
Maximum Fuel Limit sets the maximum actuator output current. If 100% is set at this
set point, the maximum actuator output current is 180 mA. Set this set point to a value
a little above the actuator output value for full load.
Display 2
These are menus to monitor input/output status.
1. Speed Signal #1
Speed Signal #1 displays the speed signal input to speed signal input channel #1.
2. Speed Signal #2
Speed Signal #2 displays the speed signal input to speed signal input channel #2.
3. KW Signal Input,%
KW Signal Input,% displays the input signal from the KW transducer in percent.
4. Spd Set Input,mA
Spd Set Input,mA displays the external remote speed setting input signal in mA.
5. Contact A Status
Contact A Status displays the status of the RUN/STOP contact (open or closed).
6. Contact B Status
Contact B Status displays the status of the IDLE SPEED/START SPEED contact (open
or closed).
7. Contact C Status
Contact C Status displays the status of the RAISE SPEED contact (open or closed).
8. Contact D Status
Contact D Status displays the status of the LOWER SPEED contact (open or closed).
9. Contact E Status
Contact E Status displays the status of the Generator Circuit Breaker Aux. (GCB AUX)
contact (open or closed).