721DSC for Marine Propulsion Application Manual 26004
Woodward
3
0
7. Fault Reset SW
Fault Reset SW is a software reset function to reset alarms. Change the set point value
to “TRUE” to reset alarms. Be sure to change the set point value back to “FALSE” after
resetting alarms.
If you have completed the adjustments, save the set points by pressing the SAVE key.
Disconnect the Hand Held Programmer from the control. Close the cover over J1 and
retighten the retaining screw.
CAUTION
To prevent possible damage to the engine resulting from improper control
settings, make sure you save the set points before removing power from
the control. Failure to save the set points before removing power from the
control causes them to revert to the previously saved settings.