Fault finding and diagnosis
Greenstar Heatslave II
ErP -
6 720 813 344 (2014/09)48
Fig. 87
8.4 Factory reset and fault codes
8.4.1 Factory reset
To reset changes made in Menu 2 back to the factory default setting:
Fig. 88
1. Press and hold the and buttons for at least
5 seconds. The screen will then display code BE with the spanner
symbol.
2. Press the button and “reset” will be displayed with the tick
symbol for 3 seconds. After 3 seconds the display will revert to the
normal operation screen.
Fig. 89
8.4.2 Locking or Blocking fault conditions
Should a fault develop with this boiler (or the system), the boiler will
enter into a Locking or Blocking condition.
Locking condition
The boiler display will flash a warning triangle.
A 3 digit cause code will flash on the display during a Locking error.
An alpha numeric fault code will be displayed indicating the fault
group.
The operation and fault indicator will flash on the front of the
appliance.
Manual intervention is required following clearance of the fault.
Press the reset button on the boiler fascia.
Blocking condition
The boiler will stop operating and no fault code will be displayed.
An alpha numeric fault code is accessed in the info menu by pressing
the spanner/return button.
A 3 digit cause code is also accessed in the info menu by pressing the
spanner/return button.
The condition will clear automatically when the associated fault
clears e.g. waiting for an area of the boiler to cool down.
In some cases a Blocking error has a defined time duration prior to
changing to a Locking condition.
2.7A Demand/fault
LED (blue light) activation
O = The blue light will only
operate as a flashing fault
alert.
1 = The blue light will operate
as a boiler operation and
fault alert.
This is set to 1 by default.
Menus 3 and Test are empty and are not used on this
appliance.
Any changes made to Menu 1 are not reset by these
actions.
6 720 805 209-67.1TL
4
6 720 805 209-68.1TL
1
ok
Unlike a Locking error, during a Blocking error (or normal
operating status), a fault code is not automatically
displayed.
reset
6 720 805 209-68.1TL
2
reset