Satellite Upconverter Manual WORK Microwave
26 / 49 V151207
3.5.3.13 ON/OFF KEYS
The item “ON/OFF KEYS” in the “SYSTEM CFG” submenu allows to enable or disable the function of the "TX
On" and "TX Off" keys. If the on/off keys are disabled (keys are not operational) by this menu item, the signal
output is only changeable through the menu point “SIGNAL OUTPUT” within the “CONV CFG” menu.
3.5.3.14 DATE/TIME SETTINGS
The submenu “DATE/TIME SETTINGS” allows access to date, time and NTP settings of the device. After this
menu item was selected the submenu can be activated by pressing the “Enter” key. The items of this sub-
menu are explained in the following:
3.5.3.14.1 DATE
The item “DATE” in the DATE/TIME SETTINGSsubmenu allows to check and set the date of the real time
clock within the unit. The date is used for logging alarms and events in the alarm or event history together
with a time stamp.
3.5.3.14.2 TIME
The item “DATE” in the DATE/TIME SETTINGSsubmenu allows to check and set the time of the real time
clock within the unit. The time is used for logging alarms and events in the alarm or event history together
with a time stamp.
3.5.3.14.3 TIME ZONE
The item “TIME ZONE” in the “DATE/TIME SETTINGS” submenu allows to select the local time zone.
3.5.3.14.4 NTP SERVER OPERATION
The item “NTP SERVER OPERATION” in the “DATE/TIME SETTINGS” submenu allows to enable or disable
the time server function. If this function is enabled the internal clock will be synchronized with a time server by
using the network time protocol (NTP).
3.5.3.14.5 NTP SERVER
The item NTP SERVER” in the “DATE/TIME SETTINGS” submenu allows to set the IP address of the NTP
server. This address can be a IPv4 or IPv6 address.
3.5.3.14.6 NTP BACKUP
The item NTP BACKUP” in the “DATE/TIME SETTINGS” submenu allows to set the IP address of the NTP
backup server. This address can be an IPv4 or an IPv6 address. The NTP backup server is used, when the
standard NTP server is not reachable.
3.5.3.14.7 NTP SYNC INTERVAL
The item “NTP SYNC INTERVAL” in the “DATE/TIME SETTINGS” submenu allows to set the time between
two NTP synchronizations. The time value is set in ms.
3.5.3.15 BANNER MODE
The item “BANNER MODE” in the “SYSTEM CFGsubmenu allows to select “USER TEXTor DEFAULT”.
The banner mode affects the string displayed in the top line of the main menu. The meaning of the settings is
as follows:
· “USER TEXT” a configurable user text string is displayed
· “DEFAULT" the default factory string is displayed
3.5.3.16 BANNER
The item “BANNER” in the “SYSTEM CFG” submenu allows to enter a string of maximum 31 characters
which is displayed in the top menu on the top line. This string can be used e.g. to indicate which channel is
handled by this unit or for any other information. This text is displayed only when in “BANNER MODE” the
option “USER TEXT” is selected.