Satellite Upconverter Manual WORK Microwave
36 / 49 V151207
y: Actual reference source:
0=int.,1=ext.
ddd:
reserved, currently 000
r:
Alarm relay: 0=disabled, 1=enabled
Warning and Alarm Bits:
a:
OCXO oven cold: 0=Ok, 1=cold
b:
Reference Alarm: 0=OK / 1=Alarm
c:
reserved, always 0
d:
reserved, always 0
e:
reserved, always 0
f:
reserved, always 0
g:
reserved, always 0
h: Mute by external input: 0=Normal, 1=Mute
4.3 Command Parameter Tables
Figure 14: Serial Interface Parameters for Command ZR
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Baud Rate
-
Mode
Baudrate:
Bit 7
Bit 6
Bit 5
Baudrate
0
0
0
4800
0
0
1
4800
0
1
0
9600
0
1
1
19200
1
0
0
38400
1
0
1
115200
Mode:
Bit 3
Bit 2
Bit 1
Bit 0
Parity
Data bits
Stop bits
0
0
0
0
EVEN
7
1
0
0
0
1
ODD
7
1
0
0
1
0
NONE
7
2
0
0
1
1
EVEN
7
2
0
1
0
0
ODD
7
2
0
1
0
1
NONE
8
1
0
1
1
0
EVEN
8
1
0
1
1
1
ODD
8
1
1
0
0
0
NONE
8
2