3.5.6 STORED EVT
The item “STORED EVT” in the main menu allows access to display the stored events of the Converter. After
this menu item was selected with the left or right arrow keys the items of the submenu belonging to this main
menu item can be activated by pressing the “Enter” key. The items of this submenu are explained in the fol-
lowing:
3.5.6.1 SHOW STORED ALARMS
The item “SHOW STORED ALARMS” in the “STORED EVT” submenu allows to display stored alarms with
time stamps. Any change in the alarm status is stored as event, so it can also be seen when the alarm disap-
peared again. If one or more alarm events are stored the LED “Stored Alarms” on the front panel is turned on.
Maximum 20 events are stored. If the alarm event memory is full, the LED “Stored Alarms” on the front panel
starts blinking.
If there are stored alarms it is possible with the “Left” and “Right” arrow keys to step through the alarm events.
With the “Up” or “Down” arrow key it is possible to display a text description for the type of alarm or that an
alarm condition had been terminated.
3.5.6.2 CLEAR ALL STORED ALARMS
The item “CLEAR ALL STORED ALARMS” in the “STORED EVT” submenu allows to clear the event log for
the stored alarms.
3.5.6.3 SHOW STORED EVENTS
The item “SHOW STORED EVENTS” in the “STORED EVT” submenu allows to display stored events with
time stamps. Events which are stored are e.g. Power Up, OCXO Oven Cold, OCXO Oven warm. The last 10
events are stored with time stamp, older events are automatically deleted. If there are stored events it is pos-
sible with the “Left” and “Right” arrow keys to step through the alarm events.
3.5.6.4 CLEAR ALL STORED EVENTS
The item “CLEAR ALL STORED EVENTS” in the “STORED EVT” submenu allows to clear the event log for
the stored events.