Rear Panel
20 Freedom HF Owner's Guide
Rear Panel
1
2
4
3
Figure 7 Rear Panel (Freedom HF 1055 EMS,1800 EMS))
Item Description
1 Negative DC cabling terminal that ispre-connected to an 18-inch
(0.45m) batterycable with an Anderson connector.
2 Ventilation grille (openings) must not be obstructed for the proper
operation of the cooling fan and inverter. When the inverter is
mounted, the ventilation grille must not point up or down.
3 Positive DC cabling terminal that is pre-connected to an 18-inch
(0.45m) batterycable
c
with an Anderson
d
connector.
4 Serial number of your unit.
c
Freedom HF 1055 EMS has a cable size of 2 AWG with SB175 Anderson connector and 1800 EMS has a
cable size of 2/0 AWG with SB350 Anderson connector.
d
Anderson Power Products® manufactures power interconnects and accessories. An Anderson connector
is a term used in this manual to mean a connector manufactured by Anderson Power Products and refers
to either SB175 or SB350.
1
2
4
3
Figure 8 Rear Panel (All Other Models)
Item Description
1 Negative DC cabling terminal connects to the negative terminal
of the battery using a battery cable.
2 Ventilation grille (openings) must not be obstructed for the proper
operation of the cooling fan and inverter. When the inverter is
mounted, the ventilation grille must not point up or down.
3 Positive DC cabling terminal connects to the positive terminal of
the battery using a battery cable.
4 Serial number of your unit.