Error Code Condition Mode Action
E01
Low battery voltage shutdown is
imminent depending on the
setting, see Operating Limits on
page 35.
Inverting Check battery status and recharge if necessary.
Check for proper DC cable sizing.
Check for loose connections and tighten if necessary.
E02
High battery voltage shutdown
> 15.5 volts DC
Inverting Check for external charging sources, such as a PV charger and an over
voltage alternator. Disconnect, if necessary.
E03
AC output overload shutdown Inverting Reduce the loads connected to the AC outlet of the unit.
Check appliancesthat have high-surge ratings and disconnect if necessary.
E04
Over-temperature shutdown Inverting Reduce the loads connected to the AC outlet of the unit.
Check that the ventilation grille isnot blocked.
Check for ambient temperature and move the unit to a cooler location
whenever possible.
E05
Low battery voltage detected
depending on setting, see
Operating Limits on page 35.
Inverting Check battery status and recharge if necessary.
Check for proper DC cable sizing.
Check for loose connections and tighten if necessary.
E06
AC output overload warning Inverting Reduce the loads connected to the AC outlet of the unit.
E07
Over-temperature warning Inverting Reduce the loads connected to the AC outlet of the unit.
Check that the ventilation grille isnot blocked.
Check for ambient temperature and move the unit to a cooler location
whenever possible.
E08
not used
E09
not used
Table 6Error codes displayed on the Display Panel screen