RS-232 Operation
TM-XDOP-01XN 4–17
Configuration
Front Panel
First set the RS-232 parameters:
Next, select RS-232 as the remote control interface.
Press the LCL/RMT button to begin remote operation via the RS-232 interface.
Step # Do This You Will See
1 ERROR MSGS
2
5 times
REMOTE CONFIG
3
RS-232 Cfg
4
Baud 9600
5
or
Select the baud rate.
Baud #####
6 Flow Ctl None
7
or
Select the flow control option.
Options are
None = no flow control
Hdwr = CTS/DTS hardware handshake
XON = software, XON/XOFF characters used
8 Settings are saved.
MENU
ENTER
ENTER
ENTER
ENTER
Step # Do This You Will See
1ERROR MSGS
2
4 times
REMOTE SELECT
3
RS-232
4 RS-232 setting is saved.
MENU
ENTER
ENTER