EasyManua.ls Logo

Xantrex XDC 10-1200 - Current Share Error Codes; Table D-13 Current Share Error Codes

Xantrex XDC 10-1200
284 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Current Share Error Codes
TM-XDOP-01XN D–9
Current Share Error Codes
Table D-13
Current Share Error Codes
Error code Error Message Description
+1900 Current Share General Error
+1911 Current share master already online
A unit on the CANbus network has already been assigned the current share
master unit. Only one is allowed per network.
+1912 Current share slave lost
One of the connected current share slaves have not responded in time.
+1921 Current share master lost
The assigned master has not responded in time.
+1922 Current share slave connection refused
Connection as a slave on the current share network has been refused due to
one of the following reasons:
4 slaves are already online,
the voltage rating does not match those of the masters,
the current rating does not match those of the masters.
+1924 Current share data out of range
The voltage or current readback or setpoint values passed are out of range.
+1925 Current share slave output off by unknown
One of the slave’s output is off because of unknown reasons
+1926 Current share slave output off by command
One of the slave’s output is off because of a command from a remote source
or the front panel.
+1927 Current share slave output off by AC fail
One of the slave’s output is off because of an AC fail condition.
+1928 Current share slave output off by OTP (Over Temperature Protection)
One of the slave’s output is off because of an OTP condition.