Protocol Specifications
TM-XDOP-01XN E–3
Protocol Specifications
Multiline Control Functions
IEEE 488.2 (Section 5) requires specific Device Interface Functions.
Interface Functions
IEEE 488.1 (Section 2).
Table E-1
Multiline Control Functions
Function Mnemonic Description Functions Subset
Source
Handshake
SH1 Complete capability SIDS, SGNS, SDYS, STRS, SWNS, SIWS
Acceptor
Handshake
AH1 Complete capability AIDS, ANRS, ACRS, ACDS, AWNS
Talker T6 Includes serial poll TIDS, TADS, TACS, SPAS, SPIS, SPMS, TPIS,
TPAS
Listener L4 LIDS, LADS, LACS, LPIS, LPAS
Table E-2
Interface Functions
Function Mnemonic Description Functions Subset
Device Clear DC1 Complete capability DCIS, DCAS
Device Trigger DT1 Complete capability DTIS, DTAS
Drivers E2 Tri state drivers where selectable
Parallel Poll PP1 Parallel Poll
Remote/Local RL1 Complete capability LOCS, LWLS, REMS, RWLS
Service
Request
SR1 Complete capability NPRS, SQRS, APRS
Controller C0 Device does not act as a controller