SCPI Command Summary
TM-XDOP-01XN C–27
Table C-11
Protection Commands
Function SCPI Command Description Query
Set Over
Temperature
Response
[:]SENSe[<channel>]:TEMPerature:PROTection:LAT
Ch <on-off-state>
Select if output is latched off or
auto recovers in the case of an
over temperature condition
Yes
Query Over
Temperature
Protection Tripped
[:]SENSe[<channel>]:TEMPerature:PROTection:TRI
Pped?
Query temperature protection
tripped
N/A
Set AC Fail
Response
[:]SENSe[<channel>]:VOLTage:AC:PROTection:LATC
h <on-off-state>
Select if output is latched off or
auto recovers in the case of an AC
Fail
Yes
Query AC Fail
Protection Tripped
[:]SENSe[<channel>]:VOLTage:AC:PROTection:TRIP
ped?
Query AC protection circuit
tripped
N/A
Table C-12
User Lines
Function SCPI Command Description Query
Select polarity of
Auxiliary Lines
[:]OUTPut[<channel>]:AUXiliary<A|B>:POLarity
{HIGH|LOW}
Configure the polarity of the
auxiliary line
Yes
Select Source of
Auxiliary Line State
[:]OUTPut[<channel>]:AUXiliary<A|B>:SOURce
<aux_line_mnemonic>
Configure the auxiliary line Yes
Query state of
Auxiliary Line
[:]OUTPut[<channel>]:AUXiliary<A|B>:STATe?
Query the state of the auxiliary
line
N/A
TM-XDOP-01XN.book Page 27 Monday, July 17, 2006 11:19 AM