SCPI Command Reference
C–18 TM-XDOP-01XN
Table C-7
Commands for Fold Protection
Function SCPI Command Description Query
Set Output Fold
Delay
[:]OUTPut[<channel>]:PROTection:FOLD:DELay
<delay>
Set the delay time (seconds)
before fold protection is triggered.
Yes
Set Output Fold
Mode
[:]OUTPut[<channel>]:PROTection:FOLD[:MODE]
{NONE|CC|CP|CV}
Select which regulation mode to
fold back (None, CV, CC, CP)
Yes
Query Fold
Protection Tripped
[:]OUTPut[<channel>]:PROTection:FOLD:TRIPped?
Query if fold protection has
tripped
N/A
Table C-8
Commands for Triggering
Function SCPI Command Description Query
Set Immediate
Initiation of Trigger
System
[:]INITiate[<channel>][:IMMediate]
Initiate a triggered event or
sequence
N/A
Set Trigger Source
[:]TRIGger[<channel>][:SEQuence]:SOURce
{BUS|EXTernal|IMMediate|NONE}
Sets the trigger source for
triggered setpoints
Yes
TM-XDOP-01XN.book Page 18 Monday, July 17, 2006 11:19 AM