FusionServer 2288H V6 Server
Technical White Paper
6 Product Specifications
2022-06-25
206
Category
Specifications
highest operating temperature decreases by 1°C (1.8°F) for
every increase of 175 m (574.14 ft).
When the server configuration complies with ASHRAE
Class A4 and the altitude is above 900 m (2952.76 ft), the
highest operating temperature decreases by 1°C (1.8°F) for
every increase of 125 m (410.1 ft).
HDDs cannot be used at an altitude of over 3050 m
(10006.44 ft).
Corrosive gaseous
contaminant
Maximum corrosion product thickness growth rate:
Copper corrosion rate test: 300 Å/month (meeting level G1
requirements of the ANSI/ISA-71.04-2013 standard on
gaseous corrosion)
Silver corrosion rate test: 200 Å/month
Particle contaminant
The equipment room environment meets the requirements
of ISO 14664-1 Class 8.
There is no explosive, conductive, magnetic, or corrosive
dust in the equipment room.
NOTE
It is recommended that the particulate pollutants in the equipment room
be monitored by a professional organization.
Acoustic noise
The declared A-weighted sound power levels (LWAd) and
declared average bystander position A-weighted sound
pressure levels (LpAm) listed are measured at 23°C (73.4°F) in
accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
Idle:
LWAd: 5.98 Bels
LpAm: 42.6 dBA
Running:
LWAd: 6.68 Bels
LpAm: 49.5 dBA
NOTE
Actual sound levels generated during server operation vary depending
on server configuration, load, and ambient temperature.