EasyManua.ls Logo

xFusion Digital Technologies FusionServer 2288H V6

xFusion Digital Technologies FusionServer 2288H V6
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FusionServer 2288H V6 Server
Technical White Paper
6 Product Specifications
2022-06-25
205
Component
Specifications
iBMC
NC-SI
Integration with third-party management systems
Security feature
Power-on password
Administrator password
TCM (only in China)/TPM
Secure boot
Front bezel (optional)
Chassis cover opening detection
Category
Specifications
Temperature
Operating temperature: 5°C to 45°C (41°F to 113°F)
(ASHRAE Classes A1 to A4 compliant)
Storage temperature (within three months): 30°C to +60°C
(22°F to 140°F)
Storage temperature (within six months): 15°C to +45°C
(5°F to 113°F)
Storage temperature (within one year): 10°C to +35°C
(14°F to 95°F)
Maximum rate of temperature change: 20°C (36°F) per
hour, 5°C (9°F) per 15 minutes
NOTE
The highest operating temperature varies depending on the server
configuration. For details, see A.3.2 2288H V6-16DIMM.
Relative Humidity (RH,
non-condensing)
Operating humidity: 8% to 90%
Storage humidity (within three months): 8% to 85%
Storage humidity (within six months): 8% to 80%
Storage humidity (within one year): 20% to 75%
Maximum humidity change rate: 20%/h
Air volume
≥204 CFM
Operating altitude
≤ 3050 m (10006.44 ft)
When the server configuration complies with ASHRAE
Classes A1 and A2 and the altitude is above 900 m
(2952.76 ft), the highest operating temperature decreases by
C (1.8°F) for every increase of 300 m (984.24 ft).
When the server configuration complies with ASHRAE
Class A3 and the altitude is above 900 m (2952.76 ft), the

Table of Contents

Related product manuals