6
E-016
CPU running
error
Hardware damaged
Contact us
7
E-017
CPU running
overtime
Program damaged
Contact us
8
E-018
FPGA running
overtime
Program damaged
Contact us
9
E-019
System
password error
Program damaged
Contact us
02
0
E-020
Parameter
loading error
Parameter self-checking
cannot pass
Re-power the servo to
restore default setting or
contact us
1
E-021
Parameter out
of range
The setting value out of
range
Check the parameters and
set again
2
E-022
Parameter
conflict
TREF or VREF
function setting conflict
1. P0-01=4, P3-00=1 will
alarm
3
E-023
Sampling
channel setting
error
User-defined output
trigger channel or data
monitor channel setting
error
Check the setting
parameter
4
E-024
Parameter lost
Power supply voltage
too low
1.for single phase 220V,
connect L1, L3
2. set the parameter again
5
E-025
Erase flash
error
Parameter store error
when power off
Contact us
6
E-026
Initialize flash
error
Flash chip power
supply not stable
Contact us
03
0
E-030
Bus
1. power grid voltage
too high
1. check the grid
fluctuation