EasyManua.ls Logo

Xinje DS5B Series - Page 61

Xinje DS5B Series
109 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
E-016
CPU running
error
Hardware damaged
Contact us
7
E-017
CPU running
overtime
Program damaged
Contact us
8
E-018
FPGA running
overtime
Program damaged
Contact us
9
E-019
System
password error
Program damaged
Contact us
02
0
E-020
Parameter
loading error
Parameter self-checking
cannot pass
Re-power the servo to
restore default setting or
contact us
1
E-021
Parameter out
of range
The setting value out of
range
Check the parameters and
set again
2
E-022
Parameter
conflict
TREF or VREF
function setting conflict
1. P0-01=4, P3-00=1 will
alarm
3
E-023
Sampling
channel setting
error
User-defined output
trigger channel or data
monitor channel setting
error
Check the setting
parameter
4
E-024
Parameter lost
Power supply voltage
too low
1.for single phase 220V,
connect L1, L3
2. set the parameter again
5
E-025
Erase flash
error
Parameter store error
when power off
Contact us
6
E-026
Initialize flash
error
Flash chip power
supply not stable
Contact us
03
0
E-030
Bus
1. power grid voltage
too high
1. check the grid
fluctuation

Table of Contents

Related product manuals