when the temperature is
higher than 85°
17
0
E-170
Motor
undervoltage
when running
Bus voltage too low
when running
1. check the power grid
voltage fluctuation
2. wait the bus voltage
stable, then repower on
20
0
E-200
Regenerative
resistor
overload
Regenerative resistor
discharging power over
the rated
Change larger power
regenerative resistor
1
E-201
Regenerative
resistor
discharge too
long time
Regenerative resistor
connection error or
value too large
Change small value
resistor and check the
wiring
22
0
E-220
Absolute
encoder
communication
error
Encoder not connect or
contactor not good
Cut off drive power, check
encoder wiring, use
multi-meter test the
connection
recived encoder data
error, and error time
over encoder error time
register P0-56 value
Not put the encoder wire
together with the strong
power supply cable, install
filter at servo drive power
supply input side, install
magnet ring around
encoder wire, far away
from large noise
equipment
2
E-222
Absolute
encoder battery
voltage low
1. The battery voltage is
lower than 3.2V
2. new motor alarm
1. Please change new
battery when the servo
power is on, the battery is

Table of Contents