104
and encounter the
forward over range
signal
2
E-262
Control stop
over time
1. inertia too big
2. stop overtime too
short
3. brake torque too
small
1. decrease the
inertia or use
motor with
brake
2. increase stop
overtime P0-30
3. increase brake
torque P3-32
28
0
E-280
Excessive
Vibration
Intensity
Strong vibration of
motor
Reduce the gain
of servo position
loop or speed
loop and check
whether the
motor shaft
connection is
firm.
30
0
E-300
Loss of
synchronization
with Motion Bus
Motion Bus
Communication
Abnormality
Check Motion
Bus Connection
31
0
E-310
Motor code
error
Motor code error
Set the correct
motor code in
P0-33
1
E-311
Motor code lost
Motor code not set
Set motor code
in P0-33