79
17
custom output 2 hysteresis
Related
to the
trigger
condition
0
0~65535
All
18
IO filter time
ms
0
0~10000
All
19
Z phase signal pulse width
ms
2
2~20
All
20
/S-ON servo signal
0000: signal is always invalid
0001: input positive signal from SI1
0002: input positive signal from SI2
0003: input positive signal from SI3
0004: input positive signal from SI4
0010: signal is always valid
0011: input negative signal from SI1
0012: input negative signal from SI2
0013: input negative signal from SI3
0014: input negative signal from SI4
000
1
1
All
21
/P-CON proportion action command
Ditto
0
1
All
22
/P-OT forward drive ban
ditto
000
3
1
All
23
/N-OT reverse drive ban
ditto
000
4
1
All
24
/ALM-RST alarm clean
ditto
000
2
1
All
25
/P-CL forward side external torque
limit
ditto
0
1
All