134
P0-33
Set the motor code
-
0
0~ffff
1|2|3|4|5|6|7|10
4.7
P0-69
Fan switch
Turn on the fan
when the
temperature
greater than 45
and turn off the
fan when less than
42
(hysteresis
3
)
1 - Turn on the fan
after enabling, turn
off the fan when
not enabling
-
1
0~1
1|2|3|4|5|6|7|10
-
P0-74
Blocking alarm
time
ms
0
0~65535
1|2|3|4|5|6|7|10
5.2.7
P0-75
Blocking alarm
speed
rpm
50
5~9999
1|2|3|4|5|6|7|10
5.2.7
P0-79
Absolute Encoder
Battery
Undervoltage
Alarm Switch
(firmware version
20160304 and
later)
0-Battery
Undervoltage
Alarm Effective
1-Shielded Battery
Undervoltage
Alarm
-
1
0~1
1|2|3|4|5|6|7|10
5.11.1
P0-80
Thermal Power
Protection of
Motor
0-current
protection
1-Average
Thermal Power
Protection
2-Analog Thermal
Power Protection
-
2
0~2
1|2|3|4|5|6|7|10
-
P0-92
P0-93
32-bit electronic
gear ratio
numerator.
take effect when
P0-11
P0-14 is
0. P0-92*1 +
P0-93 *10000
-
1
1~9999
5|6
5.3.3
1~65535
P0-94
P0-95
32-bit electronic
gear ratio
-
1
1~9999
5|6
5.3.3

Table of Contents

Other manuals for Xinje DS5E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS5E Series and is the answer not in the manual?

Xinje DS5E Series Specifications

General IconGeneral
BrandXinje
ModelDS5E Series
CategoryServo Drives
LanguageEnglish

Related product manuals