19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Gnd
+
+
Gnd
+
WS009538A
Sensor Wire number Base unit terminal
FLS - Leakage in stator housing 1 13
2 14
Pt100 - Temperature measurement, main bearing 3 8
4 4
Thermal switches - Temperature guard stator windings 5 1
6 2
FLS - Leakage in junction box 7 15
(2) (14)
Pt100 - Temperature measurement, stator winding phase 1 8 3
(4) (4)
2. Connect the pump memory.
Function Wire number Base unit terminal
RS-485 B 9 38
RS-485 A 10 37
Supply, ground (earth) 11 36
Supply, +12 V 12 35
3. When applicable, attach the cable screen to the ground (earth) terminals in the pump
and in the electrical cabinet.
5.2.2 Connect a 24-wire cable from a large pump
1. Connect the sensor wires.
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
VIS 10
Gnd
+
Gnd
Gnd
+
+
+
Gnd
+
WS009539A
5 Electrical Installation
12 MAS 711 Installation, Operation, and Maintenance Manual