EasyManua.ls Logo

Xylem FLYGT MAS 711 - Connect a 24-Wire Cable from a Large Pump

Xylem FLYGT MAS 711
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Gnd
+
+
Gnd
+
WS009538A
Sensor Wire number Base unit terminal
FLS - Leakage in stator housing 1 13
2 14
Pt100 - Temperature measurement, main bearing 3 8
4 4
Thermal switches - Temperature guard stator windings 5 1
6 2
FLS - Leakage in junction box 7 15
(2) (14)
Pt100 - Temperature measurement, stator winding phase 1 8 3
(4) (4)
2. Connect the pump memory.
Function Wire number Base unit terminal
RS-485 B 9 38
RS-485 A 10 37
Supply, ground (earth) 11 36
Supply, +12 V 12 35
3. When applicable, attach the cable screen to the ground (earth) terminals in the pump
and in the electrical cabinet.
5.2.2 Connect a 24-wire cable from a large pump
1. Connect the sensor wires.
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
VIS 10
Gnd
+
Gnd
Gnd
+
+
+
Gnd
+
WS009539A
5 Electrical Installation
12 MAS 711 Installation, Operation, and Maintenance Manual

Table of Contents

Related product manuals