EasyManua.ls Logo

Xylem MJK Shuttle - Standard Range Version;Fm Approved

Xylem MJK Shuttle
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
SW 838023
EN 2.10 Shuttle Manual 1712
Appendix
3030
0
-40
-30
-20
-10
dB
Standard Range Version/FM Approved
Shuttle
®
Ultrasonic Sensor Types 200640 / 200641
Measuring range 12 m (liquids), 6 m (solids)
Frequency 40 KHz
Spread 7 °
Dead band 35 cm
Sensitivity See figure below
Temperature - 20 to + 60 °C
Materials VALOX
Cable 200640:
Cable 200641:
Shielded, insuated with oil resistant PVC,
length 12 m.
Shielded, insuated with oil resistant PVC,
length 50 m
(Max. 100 m with 690010 cable)
Enclosure IP 68, water-proof, withstands sub-
merging, max. 1 bar
CE approvals EN 50081-1, EN 50082-1
Ex approvals FM Class 1, Div. 1, Group A-G