64
Table 4.10 “H” Parameters
Access Level
Name Address Description Data Range Unit Default
During
Run
V/f
V/f
w/PG
OLV FV OLV2
60h DC Injection Braking Command
61h Speed Search 1
62h Speed Search 2
63h Energy Savings Mode
64h Speed Search 3
65h KEB Ride Thru NC
66h KEB Ride Thru NO
67h Communication Self Test Mode
68h High Slip Braking
69h Jog 2 (3-wire Control)
6Ah drive Enable
H1-01 0400h
Digital Input Terminal S3
Function Selection
71h
Speed/Torque Changeover
Selection
1 24h - - - - -
72h Zero Servo Command
77h ASR Gain Switchover
78h
Torque Reference Polarity
Change
79h
Disable Speed Estimation (OLV2
Only)
H1-02 0401h Terminal S4 Selection See H1-01 1 14h A A A A A
H1-03 0402h Terminal S5 Selection See H1-01 1 03h A A A A A
H1-04 0403h Terminal S6 Selection See H1-01 1 04h A A A A A
H1-05 0404h Terminal S7 Selection See H1-01 1 06h A A A A A
H1-06 0405h Terminal S8 Selection See H1-01 1 08h A A A A A
H1-07 0406h Terminal S9 Selection See H1-01 1 05h A A A A A
H1-08 0407h Terminal S10 Selection See H1-01 1 32h A A A A A
H1-09 0408h Terminal S11 Selection See H1-01 1 07h A A A A A
H1-10 0409h Terminal S12 Selection See H1-01 1 15h A A A A A
0h During Run 1
1h Zero Speed
2h Fref / Fout Agree 1
3h Fref / L4-01 Agree 1
4h Frequency Detection 1
5h Frequency Detection 2
6h Inverter Ready
7h DC Bus Undervoltage
8h Baseblock 1
9h Option Reference
Ah Remote Operation
Bh Torque Detection 1 N.O.
Ch Frequency Reference Loss
Dh DB Overheat
Eh Fault
Fh
Not Used
(Set for Network Use)
10h Minor Fault (Alarm)
11h Reset Command Active
12h Timer Output
13h Fref / Fout Agree 2
14h Fref / L4-01 Agree 2
15h Frequency Detection 3
16h Frequency Detection 4
17h Torque Detection 1 N.C.
18h Torque Detection 2 N.O.
19h Torque Detection 2 N.C.
H2-01 040Bh
Digital Output Terminal
M1-M2 Function Selection
1Ah Reverse Direction
1 0h - - - - -