EasyManuals Logo

YASKAWA G7 User Manual

YASKAWA G7
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
86
Table 5.1 User Parameter Settings
Parameter
Description Default User Setting Notes
E1-03 V/F Pattern Selection 0fh
E1-04 Maximum Frequency 60.0 Hz
E1-05 Maximum Voltage kVA Dep.
E1-06 Base Frequency 60.0 Hz
E1-07 Midpoint Frequency A Control Meth
E1-08 Midpoint Voltage A Control Meth
E1-09 Minimum Frequency Control Meth
E1-10 Minimum Voltage Control Meth
E1-11 Midpoint Frequency B 0.0 Hz
E1-12 Midpoint Voltage B 0.0 VAC
E1-13 Base Voltage 0.0 VAC
E2-01 Motor Rated FLA kVA Dep.
E2-02 Motor Rated Slip kVA Dep.
E2-03 No-Load Current kVA Dep.
E2-04 Number of Poles 4
E2-05 Terminal Resistance kVA Dep.
E2-06 Leakage Inductance kVA Dep.
E2-07 Saturation Compensation 1 0.50
E2-08 Saturation Compensation 2 0.75
E2-09 Mechanical Loss 0.00 %
E2-10 Motor Iron Loss kVA Dep.
E2-11 Motor Rated Power kVA Dep.
E2-12 Saturation Compensation 3 1.30
E3-01 Control Method (Motor 2) 2
E3-02 Maximum Frequency (Motor 2)
60.0 Hz
E3-03 Maximum Voltage (Motor 2) kVA Dep.
E3-04 Base Frequency (Motor 2) 60.0 Hz
E3-05 Midpoint Frequency (Motor 2)
Control Meth
E3-06 Midpoint Voltage (Motor 2) Control Meth
E3-07 Minimum Frequency (Motor 2)
Control Meth
E3-08 Minimum Voltage (Motor 2) Control Meth
E4-01 Motor Rated FLA (Motor 2) kVA Dep.
E4-02 Motor Rated Slip (Motor 2) kVA Dep.
E4-03 No-Load Current (Motor 2) kVA Dep.
E4-04 Number of Poles (Motor 2) 4
E4-05 Terminal Resistance (Motor 2)
kVA Dep.
E4-06 Leakage Inductance (Motor 2) kVA Dep.
E4-07 Motor Rated Power (Motor 2) kVA Dep.
E4-08 Slip Comp Gain (Motor 2) Control Meth
E4-09 ASR P Gain (Motor 2) Control Meth
E4-10 ASR I Time (Motor 2) Control Meth
E4-11 Torque Comp Gain (Motor 2) Control Meth
F1-01 PG Pulses/Revolution 1024 Pulses
F1-02 PG Feedback Loss Selection 1
F1-03 PG Overspeed Selection 1
F1-04 PG Deviation Selection 3
F1-05 PG Rotation Selection 0
F1-06 PG Output Ratio 1
F1-07 PG Ramp PI/I Selection 0
F1-08 PG Overspeed Level 115 %
F1-09 PG Overspeed Time 1.0 Sec
F1-10 PG Deviation Level 10 %
F1-11 PG Deviation Time 0.5 Sec
F1-12 PG Gear Teeth 1 0
F1-13 PG Gear Teeth 2 0
F1-14 PG Loss Detection Time 2.0 Sec
F1-21 PG Pulses/Revolution (Motor 2)
1024
F1-22 PG Rotation Selection (Motor 2)
0
F1-23 PG Gear Teeth 1 (Motor 2) 0

Other manuals for YASKAWA G7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA G7 and is the answer not in the manual?

YASKAWA G7 Specifications

General IconGeneral
TypeDC Drive
Enclosure RatingIP20
Overload Capacity150% for 60 seconds
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Communication InterfaceRS-485
Humidity5 to 95% (non-condensing)
Storage Temperature-20°C to 60°C (-4°F to 140°F)