B Parameter Table
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide 181
Parameter Table
B
F4: Analog Monitor Card (AO-A3)
F5: Digital Output Card (DO-A3)
No. Name Description Setting
F4-01
Terminal V1 Function
Selection
Sets the monitor signal for output from terminal V1. Set this parameter to the last
three digits of the desired U- monitor. Some U parameters are available only in
certain control modes.
Default: 102
Min: 000
Max: 999
F4-02
Terminal V1 Gain Sets the gain for voltage output via terminal V1.
Default: 100.0%
Min: -999.9%
Max: 999.9%
F4-03
Terminal V2 Function
Selection
Sets the monitor signal for output from terminal V2. Set this parameter to the last
three digits of the desired U- monitor. Some U parameters are available only in
certain control modes.
Default: 103
Min: 000
Max: 999
F4-04
Terminal V2 Gain Sets the gain for voltage output via terminal V2.
Default: 50.0%
Min: -999.9%
Max: 999.9%
F4-05
Terminal V1 Bias Sets the amount of bias added to the voltage output via terminal V1.
Default: 0.0%
Min: -999.9%
Max: 999.9%
F4-06
Terminal V2 Bias Sets the amount of bias added to the voltage output via terminal V2.
Default: 0.0%
Min: -999.9%
Max: 999.9%
F4-07
Terminal V1 Signal Level
Selection
0: 0 to 10 V
1: -10 to 10 V
Default: 1
Min: 0
Max: 1
F4-08
Terminal V2 Signal Level
Selection
Default: 1
Min: 0
Max: 1
No. Name Description Setting
F5-01
Terminal P1-C1 Output
Selection
Sets the function for contact output terminals M1-M2, M3-M4, and photocoupler
output terminals P1 through P6.
Default: 0
Min: 0
Max: 161
F5-02
Terminal P2-C2 Output
Selection
Default: 1
Min: 0
Max: 161
F5-03
Terminal P3-C3 Output
Selection
Default: 2
Min: 0
Max: 161
F5-04
Terminal P4-C4 Output
Selection
Default: 4
Min: 0
Max: 161
F5-05
Terminal P5-C5 Output
Selection
Default: 6
Min: 0
Max: 161
F5-06
Terminal P6-C6 Output
Selection
Default: 37
Min: 0
Max: 161
F5-07
Terminal M1-M2 Output
Selection
Default: F
Min: 0
Max: 161
F5-08
Terminal M3-M4 Output
Selection
Default: F
Min: 0
Max: 161
F5-09
DO-A3 Output Mode
Selection
0: Output terminals are each assigned separate output functions.
1: Binary code output
2: Use output terminal functions selected by parameters F5-01 through F5-08.
Default: 0
Min: 0
Max: 2
TOEP_C710616_38H_7_0.book 181 ージ 015年11月11日 水曜日 午後7時40