B Parameter Table
184 YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
1A Accel/decel Ramp Selection 2
Used in conjunction with an input terminal set for “Accel/decel ramp selection 1” (H1- = 7), and
allows the drive to switch between accel/decel ramp 3 and 4.
20 to 2F External Fault
20: N.O., Always detected, ramp to stop
21: N.C., Always detected, ramp to stop
22: N.O., During run, ramp to stop
23: N.C., During run, ramp to stop
24: N.O., Always detected, coast to stop
25: N.C., Always detected, coast to stop
26: N.O., During run, coast to stop
27: N.C., During run, coast to stop
28: N.O., Always detected, Fast Stop
29: N.C., Always detected, Fast Stop
2A: N.O., During run, Fast Stop
2B: N.C., During run, Fast Stop
2C: N.O., Always detected, alarm only (continue running)
2D: N.C., Always detected, alarm only (continue running)
2E: N.O., During run, alarm only (continue running)
2F: N.C., During run, alarm only (continue running)
50 Nominal Speed Closed: Activates the nominal speed (d1-19).
51 Intermediate Speed Closed: Activates the Intermediate Speed (d1-20).
52 Releveling Speed Closed: Activates the Releveling Speed (d1-23).
53 Leveling Speed Closed: Activates the Leveling Speed (d1-26).
54 Inspection Operation Closed: Activates Inspection operation using the speed set in d1-24.
55 Rescue Operation Closed: Activates rescue operation.
56 Motor Contactor Feedback
Open: Motor contactor open
Closed: Motor contactor closed (N.O.)
57 High Speed Limit (Up) Closed: Uses the leveling speed as the maximum speed when going up.
58 High Speed Limit (Down) Closed: Uses the leveling speed as the maximum speed when going down.
5A
<44>
Motor Contactor Feedback 2
Open: Motor contactor closed (N.C.)
Closed: Motor contactor open
5B
<44>
Brake Feedback 2
Open: Brake open (N.C.)
Closed: Brake closed
5C Floor Sensor Closed: Initiate Direct Landing (S5-10 = 1)
67 Communications Test Mode
Tests the MEMOBUS/Modbus RS-485/422 interface. Displays “PASS” if the test completes
successfully.
79 Brake Feedback
Open: Brake closed
Closed: Brake open (N.O.)
<44> Available in drive software versions PRG: 7017 or later.
H1 Multi-Function Digital Input Settings
H1-
Setting
Function Description