B Parameter Table
YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide 203
Parameter Table
B
S5: Short Floor Operation
S4-05
Rescue Operation Torque
Limit
Sets the torque limit used during Rescue Operation.
Default: 100%
Min: 0%
Max: 300%
S4-06
Rescue Operation Power
Supply Selection
0: Battery
1: UPS (single-phase)
2: UPS (3-phase)
Default: 0
Min: 0
Max: 2
S4-07 UPS Power Sets the capacity of the UPS.
Default: 0.0 kVA
Min: 0.0 kVA
Max: 100.0 kVA
S4-08
UPS Operation Speed
Limit Selection
Determines how a speed limit should be applied to the Rescue Operation speed
(S4-15) when operating from a UPS.
0: Disabled
1: Enabled until Light Load Direction Search is complete
2: Enabled until stop
Default: 2
Min: 0
Max: 2
S4-12
DC Bus Voltage during
Rescue Operation
Sets the DC bus voltage during Rescue Operation.
Default: 0 V
Min: 0 V
Max: 1150 V
S4-13
Rescue Operation Power
Supply Deterioration
Detection Level
Determines at which level of backup power supply deterioration a PF5 fault is
triggered.
Default: 80%
Min: 10%
Max: 100%
S4-15
<39>
Speed Reference Selection
for Rescue Operation
Selects the speed reference used for Rescue Operation.
Default: 0
Min: 0
Max: 1
<5> Default setting is determined by the control mode (A1-02).
<39> Available in drive software versions PRG: 7016 or later.
No. Name Description Setting
S5-01
Short Floor Operation
Selection
0: Disabled
1: Enabled (Short Floor)
2: Enabled (Advance Short Floor)
Default: 0
Min: 0
Max: 2
S5-02
Nominal Speed for Short
Floor Calculation
When d1-18 (Speed Priority Selection) is set to 0 or 3, S5-02 determines the rated
speed used during Short Floor.
Default: 0.0%
Min: 0.0%
Max: 100.0%
S5-03
Short Floor Minimum
Constant Speed Time
Sets the minimum operation time when the Advanced Short Floor function is enabled
(S5-01 = 2).
Default: 0.0 s
Min: 0.0 s
Max: 2.0 s
S5-04
Distance Calculation
Acceleration Time Gain
Set for acceleration jerk compensation in Distance Calculation.
Default: 150.0%
Min: 50.0%
Max: 200.0%
S5-05
Distance Calculation
Deceleration Time Gain
Set for deceleration jerk compensation in Distance Calculation.
Default: 150.0%
Min: 50.0%
Max: 200.0%
S5-10 Stopping Method Selection
0: Disabled
1: Direct Landing
2: Leveling Distance Control
Default: 0
Min: 0
Max: 2
S5-11 Deceleration Distance Sets the deceleration distance when Stop Distance Control is enabled.
Default: 0 mm
Min: 0 mm
Max: 32767 mm
<36>
S5-12 Stop Distance Sets the stopping distance when Stop Distance Control is enabled.
Default: 0 mm
Min: 0 mm
Max: 10000 mm
<37>
No. Name Description Setting