B Parameter Table
208 YASKAWA ELECTRIC TOEP C710616 38H YASKAWA AC Drive-L1000A Quick Start Guide
U1-10 Input Terminal Status
Displays the input terminal status.
No signal output
available
U1-11 Output Terminal Status
Displays the output terminal status.
No signal output
available
U1-12 Drive Status
Displays the drive operation status.
No signal output
available
U1-13
Terminal A1 Input
Vo l t a g e
Displays the voltage input to terminal A1.
10 V: 100%
(-10 to +10 V)
0.1%
U1-14
Terminal A2 Input
Vo l t a g e
Displays the voltage input to terminal A2.
10 V: 100%
(-10 to +10 V)
0.1%
U1-16
Output Speed after Soft
Start
Displays output speed with ramp time and jerk settings. Units determined by
o1-03.
10 V: Max
frequency
(-10 to +10 V)
0.01%
<29>
U1-17
DI-A3 Option Card
Input Status
Displays the reference value input from the DI-A3 option card.
Display will appear in hexadecimal as determined by the digital card input
selection in F3-01.
3FFFF: Set (1 bit) + sign (1 bit) + 16 bit
No signal output
available
No. Name Description
Analog Output
Level
Unit
U1
-
10=00000000
Digital input 1
(terminal S1 enabled)
Digital input 2
(terminal S2 enabled)
Digital input 3
(terminal S3 enabled)
Digital input 4
(terminal S4 enabled)
Digital input 5
(terminal S5 enabled)
Digital input 6
(terminal S6 enabled)
Digital input 7
(terminal S7 enabled)
Digital input 8
(terminal S8 enabled)
1
1
1
1
1
1
1
1
YEA_co
mmon
U1
-
11=00000000
Multi-Function
Digital Output
(terminal M1-M2)
Digital Output
(terminal M3-M4)
Digital Output
(terminal M5-M6)
Multi-Function
Multi-Function
Digital Output
(terminal P1-C1)
Multi-Function
Digital Output
(terminal P2-C2)
Multi-Function
Not Used
Fault Relay
(terminal MA-MC closed
MA-MC open)
1
1
1
1
1
1
YEA_co
mmon
U1
-
12=00000000
During run
During zero-speed
During down direction
During fault reset
signal input
During speed agree
Drive ready
During alarm
detection
During fault detection
1
1
1
1
1
1
1
1
YEAco
mmon
TOEP_C710616_38H_7_0.book 208 ージ 015年11月11日 水曜日 午後7時40