EasyManua.ls Logo

YASKAWA MOTOMAN FS100

YASKAWA MOTOMAN FS100
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Parameters
FS100 6.1 Clearing the Status of Signals
6-3
HW1480724
HW1480724
6.1.3 Status of Auxiliary Relay Signals at Power Supply ON
By setting parameters from S4C080 to S4C095, it allows to set the status
of auxiliary relay signals (#70010 to #79997) at the time of when turning
the power supply ON.
For the parameter settings, refer to the table below.
6.1.4 Status of I/F Panel Signals at Power Supply ON
By setting parameters from S4C569 to S4C572, it allows to set the status
of I/F panel signals (#60010 to #60647) at the time of when turning the
power supply ON.
For the parameter settings, refer to the table below.
Parameters Auxiliary Relay
Signals
Set Values Explanation
S4C080 #70010 to #70647 (Bit
specification)
0: Clear,
1: Hold
When a bit specification is
set to "1", the status of
auxiliary relay signals will be
held at the time of power
supply ON.
(Bit specification is to be set
by a series of 32 signals.)
S4C081 #70650 to #71287
S4C082 #71290 to #71927
S4C083 #71930 to #72567
S4C084 #72570 to #73207
S4C085 #73210 to #73847
S4C086 #73850 to #74487
S4C087 #74490 to #75127
S4C088 #75130 to #75767
S4C089 #75770 to #76407
S4C090 #76410 to #77047
S4C091 #77050 to #77687
S4C092 #77690 to #78327
S4C093 #78330 to #78967
S4C094 #78970 to #79607
S4C095 #79610 to #79997
Parameters I/F Panel Signals Set Values Explanation
S4C569 #60010 to #60167 (Bit
specification)
0: Hold,
1: Clear
When a bit specification is
set to "1", the status of I/F
panel signals will be cleared
at the time of power supply
ON.
(Bit specification is to be set
by a series of 8 signals.)
S4C570 #60170 to #60327
S4C571 #60330 to #60487
S4C572 #60490 to #60647