6 Parameters
FS100 6.1 Clearing the Status of Signals
6-3
HW1480724
HW1480724
6.1.3 Status of Auxiliary Relay Signals at Power Supply ON
By setting parameters from S4C080 to S4C095, it allows to set the status
of auxiliary relay signals (#70010 to #79997) at the time of when turning
the power supply ON.
For the parameter settings, refer to the table below.
6.1.4 Status of I/F Panel Signals at Power Supply ON
By setting parameters from S4C569 to S4C572, it allows to set the status
of I/F panel signals (#60010 to #60647) at the time of when turning the
power supply ON.
For the parameter settings, refer to the table below.
Parameters Auxiliary Relay
Signals
Set Values Explanation
S4C080 #70010 to #70647 (Bit
specification)
0: Clear,
1: Hold
When a bit specification is
set to "1", the status of
auxiliary relay signals will be
held at the time of power
supply ON.
(Bit specification is to be set
by a series of 32 signals.)
S4C081 #70650 to #71287
S4C082 #71290 to #71927
S4C083 #71930 to #72567
S4C084 #72570 to #73207
S4C085 #73210 to #73847
S4C086 #73850 to #74487
S4C087 #74490 to #75127
S4C088 #75130 to #75767
S4C089 #75770 to #76407
S4C090 #76410 to #77047
S4C091 #77050 to #77687
S4C092 #77690 to #78327
S4C093 #78330 to #78967
S4C094 #78970 to #79607
S4C095 #79610 to #79997
Parameters I/F Panel Signals Set Values Explanation
S4C569 #60010 to #60167 (Bit
specification)
0: Hold,
1: Clear
When a bit specification is
set to "1", the status of I/F
panel signals will be cleared
at the time of power supply
ON.
(Bit specification is to be set
by a series of 8 signals.)
S4C570 #60170 to #60327
S4C571 #60330 to #60487
S4C572 #60490 to #60647