6 Parameters
FS100 6.2 Allocation of General Input Signals to Interface Panel Screens
6-4
HW1480724
HW1480724
6.2 Allocation of General Input Signals to Interface Panel
Screens
By setting general input signal numbers to parameters from S4C597 to
S4C607, general input signals can be allocated to interface panel screens.
For the parameter settings, refer to the table below.
6.2.1 Notification of the Status of General Input Signals
1. Set general input signal numbers to the parameters from S4C597 to
S4C607. (Set values are available from 1 to 1024)
– When the general input signal set to the parameter turns ON, the
Interface panel gets activated automatically and the corresponding
panel screen appears.
– If there are several corresponding screens, the panel of smaller
number appears on the display.
However, when the signal set to S4C597 (which has no
corresponding panel) turns ON, the panel screen of the previous
one appears on the display.
– When the signals set from S4C598 to S4C607 turn ON, the page
button (on which the group name is indicated) changes its color in
the corresponding panel
Parameters Corresponding
Panel Screens
Set Values Explanation
S4C597 NONE 0: No function
1 to 1024
(Integral
number):
General input
signal
numbers
Allocates the general input
signals set for parameters
to the panel screens
corresponded to the
parameters.
S4C598 Panel 1
S4C599 Panel 2
S4C600 Panel 3
S4C601 Panel 4
S4C602 Panel 5
S4C603 Panel 6
S4C604 Panel 7
S4C605 Panel 8
S4C606 Panel 9
S4C607 Panel 10
SUPPLE
-MENT
In the cases below, the [I/F Panel] button flashes in the lower
left of the display notifying the "ON" status of the general
input signals set for the parameters.
• The case when the Interface panels are unable to get acti-
vated (during imputing characters or numeric values) when
the general input signals set for the parameters turn ON.
• The case when a page button of the corresponding panel is
not shown when the general input signals set for the
parameters turn ON.