6 Parameters
FS100 6.1 Clearing the Status of Signals
6-1
HW1480724
HW1480724
6 Parameters
6.1 Clearing the Status of Signals
By setting parameters, input/output signals at the time of power supply ON
or mode change can be set to "hold" or "clear".
The possible settings and the timing of status signal settings are as
follows:
*Notice that auxiliary relay signals have different set values of parameters
from general output signals or I/F panel signals.
"Hold" and " Clear" of the status of signlas are defined as follows:
• "Hold " means to keep the status of the previous one at the time of
when the power supply is turned OFF or the mode is changed.
• "Clear" means to turn the status of signals into OFF regardless of the
previous status at the time of when the power supply is turned OFF
or the mode is changed.
Signals Timing of setting
the status of
signals
Parameters Set values
General output
signals
Mode change S4C064 to S4C079 0: Hold / 1: Clear
General output
signals
Power supply ON S2C235 0: Hold / 1: Clear
Auxiliary relay
signals
Power supply ON S4C080 to S4C095 0: Clear / 1: Hold
I/F panel
signals
Power supply ON S4C569 to S4C572 0: Hold / 1: Clear