3 Data Setting and Touch Panel I/F Instructions
FS100 3.2 Details on Interface Panel Setting Items
3-12
HW1480724
HW1480724
3.2 Details on Interface Panel Setting Items
The following describe details on the setting items of the Interface
panel screen.
Refer to them as required when setting the Interface panel data.
Table 3-2: Data of Each Setting Items (Sheet 1 of 2)
No. Items Explanations
1 Arrangement 32 positions in total: 1A to 4H
2 Setup 0: INVALID, 1: VALID
VALID INVALID: the setup status can be changed from Valid to Invalid without
conditions.
INVALID VALID: When the set parameter is OK after checking, the status can be
changed from Invalid to Valid.
The following setting is required for VALID status:
<When Icon type is circle, square, or selector switch>
Input: Signal
Output: none or within the range of general output signals
<When Icon type is counter>
Input: B-variable, I-variable, or register
<When Icon type is preset counter>
Input: B-variable, I-variable, or register
Output: B-variable, I-variable, or register
* If the setting item is edited in the Valid status, the status
becomes Invalid.
3 Panel Type 0:Circle indication light (display only)
2:Circle indication light (push-lock/push-
release button)
4:Square indication light 1 (push button)
6:Square indication light 2 (display only)
8:Square indication light 2 (push-lock/
push-release button)
10:Selector switch (right: ON)
12:Selector switch (panel operation)
16:Counter (3-digit display)
18:Preset counter (3-digit display)
1:Circle indication light (push button)
3:Square indication light 1 (display only)
5:Square indication light 1 (push-lock/
push-release button)
7:Square indication light 2 (push button)
9:Selector switch (left: ON)
11:Selector switch (2-point output)
17:Counter (6-digit display)
19:Preset counter (6-digit display)
4 Panel Color 0: Black, 1: Blue, 2: Green, 3: Sky blue, 4: Red, 5: Purple, 6: Yellow,
7: White, 8: Light gray, 9: Dark blue, 10: Dark green, 11: Dark sky blue, 12: Dark red,
13: Dark purple, 14: Dark yellow, 15: Dark gray,
16: Orange
5 Panel Name 10 one-byte characters for one line
Three lines can be indicated at maximum.
6 Text Color 0: Black, 1: Blue, 2: Green, 3: Sky blue, 4: Red, 5: Purple, 6: Yellow,
7: White, 8: Light gray, 9: Dark blue, 10: Dark green, 11: Dark sky blue, 12: Dark red,
13: Dark purple, 14: Dark yellow, 15: Dark gray,
16: Orange
7 Security 0: Operation mode, 1: Editing mode, 2: Management mode
8 Interlock Enable 0: Prohibited, 1: Permitted
9 Input ID 0: None, 1: Signal, 2: B-variable, 3: I-variable, 4: Register
No. Numbers differ according to the ID.
(See the table table 3-3 “Input/Output Allocation Status” at page 3-14.)
Contact OFF: A-contact, ON: B-contact
The setting is invalid when the ID is not set to 1:Signal.