3 Data Setting and Touch Panel I/F Instructions
FS100 3.2 Details on Interface Panel Setting Items
3-14
HW1480724
HW1480724
See the following table "Input/Output Allocation Status" when allo-
cating input/output signals.
Table 3-3: Input/Output Allocation Status
ID Items Range Input
Allocation
Output
Allocation
Icon Type
1 General input #00010 to #01287 (1024 signals) enable disable Circle/Square indication
light
Selector switch
General
output
#10010 to #11287 (1024 signals) enable enable Circle/Square indication
light
Selector switch
External input #20010 to #21287 (1024 signals) enable disable Circle/Square indication
light
Selector switch
External
output
#30010 to #31287 (1024 signals) enable enable Circle/Square indication
light
Selector switch
Special input #40010 to #41607 (1280 signals) enable disable Circle/Square indication
light
Selector switch
Special output #50010 to #52007 (1600 signals) enable disable Circle/Square indication
light
Selector switch
I/F panel #60010 to #60647 (512 signals) enable enable Circle/Square indication
light
Selector switch
Auxiliary relay #70010 to #79997 (7992 signals) enable disable Circle/Square indication
light
Selector switch
Control input #80010 to #80647 (512 signals) enable disable Circle/Square indication
light
Selector switch
Pseudo input #82010 to #82207 (160 signals) enable disable Circle/Square indication
light
Selector switch
DL input #25010 to #26287 (1024 signals) enable disable Circle/Square indication
light
Selector switch
DL output #35010 to #36287 (1024 signals) enable enable Circle/Square indication
light
Selector switch
2 B-variable B000 to B099
(100 signals)
enable - Counter
enable enable Preset counter
3 I-variable I000 to I099
(100 signals)
enable - Counter
enable enable Preset counter
4 Register Input allocation:
M000 to M999
(1000 signals)
Output allocation:
M000 to M559
(560 signals)
enable - Counter
enable enable Preset counter
SUPPLE
-MENT
The table above describes the status of input / output alloca-
tion on Interface panel.
Don’t refer to this allocation table when allocating input/out-
put signals for Concurrent I/O program.