3 Data Setting and Touch Panel I/F Instructions
FS100 3.2 Details on Interface Panel Setting Items
3-15
HW1480724
HW1480724
NOTE
• Note that the following two signals are assumed to be
unused for OUT/GOUT in the CIO program.
External output #30010 to #31287: Output allocation: enable
DL output
#35010 to #36287: Output allocation: enable
• The "Setup" box cannot be enabled if a signal used for the
OUT/GOUT command in the CIO program is assigned as
output in the I/F panel.
The 4240 error will occur ("Relay No.duplicated in CIO pro-
gram and I/F panel").
• While a signal is in IO simulation, assigning that signal as
output in the I/F panel prohibits the toggling of signal's ON/
OFF state in the I/F panel. Message: "Signal state cannot
change in I/O simulation mode"