5 PLC Setting
5.1 Master setting
5-2
HW1483854
HW1483854
4. Perform the setting of parameter. Select [Parameter] - [Network 
Parameter] - [Ethernet / CC IE Field] of the project tree.  Then the 
setting window of network parameter.  
Perform the setting of unit1 depending on the user’s network 
environment.  (Network Type, Start I/O No., Network No., Total 
Stations) 
5. Select [Network Configuration Settings] of network parameter setting 
window in step4 to perform the setting of network configuration.  
Perform setting of the local station as below (Station No.,Station type, 
RX/RY Setting, RWw/RWr Setting).  The following setting is an 
example, perform setting to suit the setting which is performed in 
maintenance mode of YRC1000.  After setting, select [End].  
㻨㻾㼄㻛㻾㼅㻪
㻼㼛㼕㼚㼠䠖㻌㼎㼕㼠
㻨㻾㼃㼞㻛㻾㼃㼣㻪
㻼㼛㼕㼚㼠㻦 㻌㼣㼛㼞㼐