5 PLC Setting
5.1 Master setting
5-2
HW1483854
HW1483854
4. Perform the setting of parameter. Select [Parameter] - [Network
Parameter] - [Ethernet / CC IE Field] of the project tree. Then the
setting window of network parameter.
Perform the setting of unit1 depending on the user’s network
environment. (Network Type, Start I/O No., Network No., Total
Stations)
5. Select [Network Configuration Settings] of network parameter setting
window in step4 to perform the setting of network configuration.
Perform setting of the local station as below (Station No.,Station type,
RX/RY Setting, RWw/RWr Setting). The following setting is an
example, perform setting to suit the setting which is performed in
maintenance mode of YRC1000. After setting, select [End].