5 PLC Setting
5.1 Master setting
5-3
HW1483854
HW1483854
6. Select [Network Operation Settings] in the network parameter setting
window in step4 to set the network operation. After setting, select
[End].
7. Select [Refresh Parameters] in the network parameter setting window
in step4 to set the refresh parameters. The following setting is an
example. After setting, select [End].
8. Select [Interrupt Settings] in the network parameter setting window in
step4 to set the interrupt setting. Perform the setting as needed. After
setting, select [End].
<CPU Side Setting>
SB, SW: Set "SB" or "SW" to "Dev.Name",
and set "0000" to "Start"
RX: Set "X" to "Dev.Name", and set "1000" to "Start"
RY: Set "Y" to "Dev.Name", and set "1000" to "Start"
RWr: Set "W" to "Dev.Name", and set "000000" to "Start"
RWw: Set "W" to "Dev.Name", and set "001000" to "Start"
<Link Side Setting>
Confirm that the local station's
address of network configration
which is set in step5 is
included above.
ࠉࠉࠉࠉࠉ
42/53