8.7 Absolute Encoders
8-35
Operation
8
7. Return to the SigmaWin for Σ-V-SD (MT) component main window. To make the settings for the
motor, click Setup and then click Multi-Turn Limit Setting again. A verification message
appears confirming if you want to continue although the position data will change.
8. Click Continue, and the Multi-Turn Limit Setting box appears. To change the settings, click Re-
Change.
9. To s a ve t h e sett i n g s, c l i c k Writing into the Motor, and a warning message appears.
10. Click OK.