12 Appendix
12-24
Pn533
(2142h:3)
2
Program JOG
Movement Speed
1 to 10000
1 min
-1
500
Immedi-
ately
Setup
spindle
motor,
servo-
motor
Pn534
(2142h:4)
2
Program JOG Accelera-
tion/Deceleration Time
2 to 10000 1 ms 100
Immedi-
ately
Setup
spindle
motor,
servo-
motor
Pn535
(2142h:5)
2
Program JOG Waiting
Time
0 to 10000 1 ms 100
Immedi-
ately
Setup
spindle
motor,
servo-
motor
Pn536
(2142h:6)
2
Number of Times of
Program JOG Movement
0 to 1000 1 time 1
Immedi-
ately
Setup
spindle
motor,
servo-
motor
Pn541
(2098h:1)
2Rated Speed Setting 100 to 65535
1 min
-1
65535 After restart Setup
spindle
motor
Pn542
(2098h:2)
2
Speed Coincidence
Detection Width
10 to 50 1% 15
Immedi-
ately
Setup
spindle
motor
Pn543
(2098h:3)
2Speed Detection Level 0 to 10000 0.01% 1000
Immedi-
ately
Setup
spindle
motor
Pn544
(2098h:4)
2
Speed Detection
Hysteresis
0 to 10000 0.01% 100
Immedi-
ately
Setup
spindle
motor
Pn545
(2098h:5)
2
Speed Error Excessive
Protection Select Switch
0000 to 0031 0000
Immedi-
ately
Setup
spindle
motor
(cont’d)
Parameter
No.
(Index No.)
Size Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Motor
Type
Reference
Section
Detection Range of Speed Error Excessive Protection
0 1/2 or less of speed reference
1 1/4 or less of speed reference
Delay Time of Speed Error Excessive Protection
0 0 ms
1 300 ms
2 400 ms
3 500 ms
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.


Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA UAK series and is the answer not in the manual?

YASKAWA UAK series Specifications

General IconGeneral
BrandYASKAWA
ModelUAK series
CategoryServo Drives
LanguageEnglish

Related product manuals