4.2 SERVOPACK
4-15
Specifications and External Dimensions for Σ-V-SD Drivers
4
Model: CACR-JU125ACA
The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink.
Model: CACR-JU196ACA
The cooling air speed of heat sink must be at least 2.5 m/s at the point closest to the heat sink.
338
365
±
0.5
130
±
0.5
10
5
140
150
15.5
7.5
380
7.5
(10)
130
150
10
(7.5)
365
(145)
300
200
5
(100)
23
334
136
7
(23)
(7)
(115
°
)
(135
°
)
200V
4-M5 Screw Holes
SERVOPACK
Rear View
Through Hole
Mounting Hole Diagram
(Mounting Pitch)
Model
Number
Input Voltage
Nameplate
4-6 Dia.
Ground
Terminal
2-M5 Screws
Cooling Fan
Heat Sink
Air Flow
Air Flow
Unit: mm
Approx. Mass: 12.0 kg
(Mounting Pitch)
380
338
365
±
0.5
200
±
0.5
25
230
250
15.5
7.5
380
7.5
(25)
200
250
25
(7.5)
365
216.5
15
(18.5)
(140)
296
200
10
(96)
23
334
(23)
(115
°
)
(
135
°
)
4-M6 Screw Holes
SERVOPACK
Rear View
Through Hole
Mounting Hole Diagram
(Mounting Pitch)
Model
Number
Input Voltage
Nameplate
4-7 Dia.
Ground Terminal
M6 Screws
Cooling Fan
Heat Sink
Air Flow
Air Flow
(Mounting Pitch)
380
Unit: mm
Approx. Mass: 20.0 kg