1 Safety Instructions and General Warnings
EN 6 YASKAWA Europe TOEP C710606 101A - V1000 MMD IP65 Motor Mounted Drive - Quick Start Guide
Never short the output circuits of the drive.
Do not short the output circuits of the drive. Failure to comply could result in death or serious
injury.
Sudden Movement Hazard
Stay clear of the motor during rotational Auto-Tuning. The motor may start operating
suddenly.
During automatic starting of equipment, the machine may start moving suddenly, which could
result in death or serious injury.
System may start unexpectedly upon application of power, resulting in death or serious
injury.
Clear all personnel from the drive, motor, and machine area before applying power. Secure
covers, couplings, shaft keys, and machine loads before applying power to the drive.
Fire Hazard
Do not use an improper voltage source.
Failure to comply could result in death or serious injury by fire.
Verify that the rated voltage of the drive matches the voltage of the incoming power supply
before applying power.
Do not use improper combustible materials.
Failure to comply could result in death or serious injury by fire.
Attach the drive to metal or other noncombustible material.
Do not connect AC line power to output terminals U, V, and W.
Make sure that the power supply lines are connected to the EMC filter inputs L1, L2, L3
and PE.
Do not connect the AC power line to the output motor terminals of the drive. Failure to comply
could result in death or serious injury by fire as a result of drive damage from line voltage
application to output terminals.
Tighten all terminal screws to the specified tightening torque.
Loose electrical connections could result in death or serious injury by fire due to overheating of
electrical connections.
CAUTION
Burn Hazard
Do not touch the heatsink or braking resistor hardware until a powered-down cooling
period has elapsed.
WARNING
WWW.NNC.IR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA V1000 MMD and is the answer not in the manual?

YASKAWA V1000 MMD Specifications

General IconGeneral
SeriesV1000
ModelMMD
Input Voltage200-240 VAC, 380-480 VAC
Output Power0.4 kW to 315 kW
Control MethodV/f control
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Short circuit